"""Sensor platform for CentriConnect/MyPropane API integration."""
|
|
|
|
from collections.abc import Callable
|
|
from dataclasses import dataclass
|
|
from datetime import datetime
|
|
from enum import StrEnum
|
|
|
|
from homeassistant.components.sensor import (
|
|
EntityCategory,
|
|
SensorDeviceClass,
|
|
SensorEntity,
|
|
SensorEntityDescription,
|
|
SensorStateClass,
|
|
StateType,
|
|
UnitOfTemperature,
|
|
)
|
|
from homeassistant.const import (
|
|
PERCENTAGE,
|
|
SIGNAL_STRENGTH_DECIBELS_MILLIWATT,
|
|
UnitOfElectricPotential,
|
|
UnitOfLength,
|
|
UnitOfVolume,
|
|
)
|
|
from homeassistant.core import HomeAssistant
|
|
from homeassistant.helpers.entity_platform import AddConfigEntryEntitiesCallback
|
|
|
|
from .coordinator import CentriConnectConfigEntry, CentriConnectCoordinator
|
|
from .entity import CentriConnectBaseEntity
|
|
|
|
# Coordinator is used to centralize the data updates.
|
|
PARALLEL_UPDATES = 0
|
|
|
|
|
|
_ALERT_STATUS_VALUES = {
|
|
"No Alert": "no_alert",
|
|
"Low Level": "low_level",
|
|
"Critical Level": "critical_level",
|
|
}
|
|
|
|
|
|
class CentriConnectSensorType(StrEnum):
|
|
"""Enumerates CentriConnect sensor types exposed by the device."""
|
|
|
|
ALERT_STATUS = "alert_status"
|
|
ALTITUDE = "altitude"
|
|
BATTERY_LEVEL = "battery_level"
|
|
BATTERY_VOLTAGE = "battery_voltage"
|
|
DEVICE_TEMPERATURE = "device_temperature"
|
|
LAST_POST_TIME = "last_post_time"
|
|
LATITUDE = "latitude"
|
|
LONGITUDE = "longitude"
|
|
LTE_SIGNAL_LEVEL = "lte_signal_level"
|
|
LTE_SIGNAL_STRENGTH = "lte_signal_strength"
|
|
NEXT_POST_TIME = "next_post_time"
|
|
SOLAR_LEVEL = "solar_level"
|
|
SOLAR_VOLTAGE = "solar_voltage"
|
|
TANK_LEVEL = "tank_level"
|
|
TANK_REMAINING_VOLUME = "tank_remaining_volume"
|
|
TANK_SIZE = "tank_size"
|
|
|
|
|
|
@dataclass(frozen=True, kw_only=True)
|
|
class CentriConnectSensorEntityDescription(SensorEntityDescription):
|
|
"""Description of a CentriConnect sensor entity."""
|
|
|
|
key: CentriConnectSensorType
|
|
value_fn: Callable[[CentriConnectCoordinator], StateType | datetime | None]
|
|
|
|
|
|
ENTITIES: tuple[CentriConnectSensorEntityDescription, ...] = (
|
|
CentriConnectSensorEntityDescription(
|
|
key=CentriConnectSensorType.ALERT_STATUS,
|
|
translation_key=CentriConnectSensorType.ALERT_STATUS,
|
|
device_class=SensorDeviceClass.ENUM,
|
|
options=list(_ALERT_STATUS_VALUES.values()),
|
|
value_fn=lambda coord: _ALERT_STATUS_VALUES.get(coord.data.alert_status),
|
|
),
|
|
CentriConnectSensorEntityDescription(
|
|
key=CentriConnectSensorType.ALTITUDE,
|
|
translation_key=CentriConnectSensorType.ALTITUDE,
|
|
native_unit_of_measurement=UnitOfLength.METERS,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
device_class=SensorDeviceClass.DISTANCE,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
entity_registry_enabled_default=False,
|
|
suggested_display_precision=2,
|
|
value_fn=lambda coord: coord.data.altitude,
|
|
),
|
|
CentriConnectSensorEntityDescription(
|
|
key=CentriConnectSensorType.BATTERY_LEVEL,
|
|
translation_key=CentriConnectSensorType.BATTERY_LEVEL,
|
|
native_unit_of_measurement=PERCENTAGE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
device_class=SensorDeviceClass.BATTERY,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
value_fn=lambda coord: coord.data.battery_level,
|
|
),
|
|
CentriConnectSensorEntityDescription(
|
|
key=CentriConnectSensorType.BATTERY_VOLTAGE,
|
|
translation_key=CentriConnectSensorType.BATTERY_VOLTAGE,
|
|
native_unit_of_measurement=UnitOfElectricPotential.VOLT,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
device_class=SensorDeviceClass.VOLTAGE,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
entity_registry_enabled_default=False,
|
|
suggested_display_precision=0,
|
|
value_fn=lambda coord: coord.data.battery_voltage,
|
|
),
|
|
CentriConnectSensorEntityDescription(
|
|
key=CentriConnectSensorType.DEVICE_TEMPERATURE,
|
|
translation_key=CentriConnectSensorType.DEVICE_TEMPERATURE,
|
|
native_unit_of_measurement=UnitOfTemperature.FAHRENHEIT,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
device_class=SensorDeviceClass.TEMPERATURE,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
entity_registry_enabled_default=False,
|
|
suggested_display_precision=1,
|
|
value_fn=lambda coord: coord.data.device_temperature,
|
|
),
|
|
CentriConnectSensorEntityDescription(
|
|
key=CentriConnectSensorType.LTE_SIGNAL_LEVEL,
|
|
translation_key=CentriConnectSensorType.LTE_SIGNAL_LEVEL,
|
|
native_unit_of_measurement=PERCENTAGE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
suggested_display_precision=0,
|
|
value_fn=lambda coord: coord.data.lte_signal_level,
|
|
),
|
|
CentriConnectSensorEntityDescription(
|
|
key=CentriConnectSensorType.LTE_SIGNAL_STRENGTH,
|
|
translation_key=CentriConnectSensorType.LTE_SIGNAL_STRENGTH,
|
|
native_unit_of_measurement=SIGNAL_STRENGTH_DECIBELS_MILLIWATT,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
device_class=SensorDeviceClass.SIGNAL_STRENGTH,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
entity_registry_enabled_default=False,
|
|
value_fn=lambda coord: coord.data.lte_signal_strength,
|
|
),
|
|
CentriConnectSensorEntityDescription(
|
|
key=CentriConnectSensorType.SOLAR_LEVEL,
|
|
translation_key=CentriConnectSensorType.SOLAR_LEVEL,
|
|
native_unit_of_measurement=PERCENTAGE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
suggested_display_precision=0,
|
|
value_fn=lambda coord: coord.data.solar_level,
|
|
),
|
|
CentriConnectSensorEntityDescription(
|
|
key=CentriConnectSensorType.SOLAR_VOLTAGE,
|
|
translation_key=CentriConnectSensorType.SOLAR_VOLTAGE,
|
|
native_unit_of_measurement=UnitOfElectricPotential.VOLT,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
device_class=SensorDeviceClass.VOLTAGE,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
entity_registry_enabled_default=False,
|
|
suggested_display_precision=0,
|
|
value_fn=lambda coord: coord.data.solar_voltage,
|
|
),
|
|
CentriConnectSensorEntityDescription(
|
|
key=CentriConnectSensorType.TANK_LEVEL,
|
|
translation_key=CentriConnectSensorType.TANK_LEVEL,
|
|
native_unit_of_measurement=PERCENTAGE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
value_fn=lambda coord: coord.data.tank_level,
|
|
),
|
|
CentriConnectSensorEntityDescription(
|
|
key=CentriConnectSensorType.TANK_REMAINING_VOLUME,
|
|
translation_key=CentriConnectSensorType.TANK_REMAINING_VOLUME,
|
|
native_unit_of_measurement=UnitOfVolume.GALLONS,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
device_class=SensorDeviceClass.VOLUME_STORAGE,
|
|
suggested_display_precision=2,
|
|
value_fn=lambda coord: (
|
|
coord.data.tank_remaining_volume
|
|
if coord.device_info.tank_size_unit == "Gallons"
|
|
else None
|
|
),
|
|
),
|
|
CentriConnectSensorEntityDescription(
|
|
key=CentriConnectSensorType.TANK_REMAINING_VOLUME,
|
|
translation_key=CentriConnectSensorType.TANK_REMAINING_VOLUME,
|
|
native_unit_of_measurement=UnitOfVolume.LITERS,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
device_class=SensorDeviceClass.VOLUME_STORAGE,
|
|
suggested_display_precision=2,
|
|
value_fn=lambda coord: (
|
|
coord.data.tank_remaining_volume
|
|
if coord.device_info.tank_size_unit == "Liters"
|
|
else None
|
|
),
|
|
),
|
|
CentriConnectSensorEntityDescription(
|
|
key=CentriConnectSensorType.TANK_SIZE,
|
|
translation_key=CentriConnectSensorType.TANK_SIZE,
|
|
native_unit_of_measurement=UnitOfVolume.GALLONS,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
device_class=SensorDeviceClass.VOLUME_STORAGE,
|
|
suggested_display_precision=2,
|
|
value_fn=lambda coord: (
|
|
coord.device_info.tank_size
|
|
if (coord.device_info.tank_size_unit == "Gallons")
|
|
else None
|
|
),
|
|
),
|
|
CentriConnectSensorEntityDescription(
|
|
key=CentriConnectSensorType.TANK_SIZE,
|
|
translation_key=CentriConnectSensorType.TANK_SIZE,
|
|
native_unit_of_measurement=UnitOfVolume.LITERS,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
device_class=SensorDeviceClass.VOLUME_STORAGE,
|
|
suggested_display_precision=2,
|
|
value_fn=lambda coord: (
|
|
coord.device_info.tank_size
|
|
if (coord.device_info.tank_size_unit == "Liters")
|
|
else None
|
|
),
|
|
),
|
|
)
|
|
|
|
|
|
async def async_setup_entry(
|
|
hass: HomeAssistant,
|
|
entry: CentriConnectConfigEntry,
|
|
async_add_entities: AddConfigEntryEntitiesCallback,
|
|
) -> None:
|
|
"""Set up CentriConnect sensor entities from a config entry."""
|
|
async_add_entities(
|
|
CentriConnectSensor(entry.runtime_data, description)
|
|
for description in ENTITIES
|
|
if description.value_fn(entry.runtime_data) is not None
|
|
)
|
|
|
|
|
|
class CentriConnectSensor(CentriConnectBaseEntity, SensorEntity):
|
|
"""Representation of a CentriConnect sensor entity."""
|
|
|
|
entity_description: CentriConnectSensorEntityDescription
|
|
|
|
@property
|
|
def native_value(self) -> StateType | datetime | None:
|
|
"""Return the state of the sensor."""
|
|
return self.entity_description.value_fn(self.coordinator)
|