"""Support for Fronius binary sensors."""
from dataclasses import dataclass
from typing import TYPE_CHECKING, override
from homeassistant.components.binary_sensor import (
BinarySensorEntity,
BinarySensorEntityDescription,
)
from homeassistant.const import EntityCategory, Platform
from homeassistant.core import HomeAssistant, callback
from homeassistant.helpers.entity_platform import AddConfigEntryEntitiesCallback
from .entity import FroniusEntity, FroniusEntityDescription
if TYPE_CHECKING:
from . import FroniusConfigEntry
from .coordinator import FroniusPowerFlowUpdateCoordinator
PARALLEL_UPDATES = 0
@dataclass(frozen=True)
class FroniusBinarySensorEntityDescription(
FroniusEntityDescription, BinarySensorEntityDescription
):
"""Describes Fronius binary sensor entity."""
POWER_FLOW_BINARY_SENSOR_DESCRIPTIONS: list[FroniusBinarySensorEntityDescription] = [
FroniusBinarySensorEntityDescription(
key="backup_mode",
),
FroniusBinarySensorEntityDescription(
key="battery_standby",
entity_category=EntityCategory.DIAGNOSTIC,
),
]
async def async_setup_entry(
hass: HomeAssistant,
config_entry: FroniusConfigEntry,
async_add_entities: AddConfigEntryEntitiesCallback,
) -> None:
"""Set up Fronius binary sensor entities based on a config entry."""
solar_net = config_entry.runtime_data
if solar_net.power_flow_coordinator is not None:
solar_net.power_flow_coordinator.add_entities_for_seen_keys(
async_add_entities, Platform.BINARY_SENSOR, PowerFlowBinarySensor
)
class PowerFlowBinarySensor(FroniusEntity, BinarySensorEntity):
"""Defines a Fronius power flow binary sensor entity."""
entity_description: FroniusBinarySensorEntityDescription
def __init__(
self,
coordinator: FroniusPowerFlowUpdateCoordinator,
description: FroniusBinarySensorEntityDescription,
solar_net_id: str,
) -> None:
"""Set up an individual Fronius power flow binary sensor."""
super().__init__(coordinator, description, solar_net_id)
self._attr_is_on = self._device_data()[self.response_key]["value"]
# SolarNet device is already created in FroniusSolarNet._create_solar_net_device
self._attr_device_info = coordinator.solar_net.system_device_info
self._attr_unique_id = (
f"{coordinator.solar_net.solar_net_device_id}-power_flow-{description.key}"
)
@callback
@override
def _handle_coordinator_update(self) -> None:
"""Handle updated data from the coordinator."""
try:
self._attr_is_on = self._device_data()[self.response_key]["value"]
except KeyError:
# KeyError: raised when omitted in response, e.g. when backup power
# is deactivated after the entity was created
self._attr_is_on = None
self.async_write_ha_state()