"""Common fixtures for the Ouman EH-800 tests."""
|
|
|
|
from collections.abc import Generator
|
|
from contextlib import nullcontext
|
|
from unittest.mock import AsyncMock, patch
|
|
|
|
from ouman_eh_800_api import (
|
|
HomeAwayControl,
|
|
L1BaseEndpoints,
|
|
L1ConstantTempMode,
|
|
L1FivePointCurve,
|
|
L1NoRoomSensor,
|
|
L1RoomSensor,
|
|
L1ThreePointCurve,
|
|
L2BaseEndpoints,
|
|
L2FivePointCurve,
|
|
L2NoRoomSensor,
|
|
L2RoomSensor,
|
|
L2ThreePointCurve,
|
|
OperationMode,
|
|
OumanEndpoint,
|
|
OumanRegistry,
|
|
OumanRegistrySet,
|
|
OumanValues,
|
|
PumpSummerStopControl,
|
|
RelayControl,
|
|
RelayL1ValvePosition,
|
|
RelayPumpSummerStop,
|
|
RelayTempDifference,
|
|
RelayTemperature,
|
|
RelayTimeProgram,
|
|
SystemEndpoints,
|
|
)
|
|
import pytest
|
|
|
|
from homeassistant.components.ouman_eh_800.const import DOMAIN
|
|
from homeassistant.const import CONF_PASSWORD, CONF_URL, CONF_USERNAME
|
|
from homeassistant.core import HomeAssistant
|
|
|
|
from tests.common import MockConfigEntry
|
|
|
|
TEST_URL = "http://192.168.1.100"
|
|
TEST_USERNAME = "test-user"
|
|
TEST_PASSWORD = "test-pass"
|
|
|
|
# Realistic value for every endpoint the API can return. Each scenario picks
|
|
# the subset for its registries, so a single endpoint is defined here once.
|
|
_ENDPOINT_VALUES: dict[OumanEndpoint, OumanValues] = {
|
|
# System
|
|
SystemEndpoints.TREND_SAMPLE_INTERVAL: 600.0,
|
|
SystemEndpoints.HOME_AWAY_MODE: HomeAwayControl.HOME,
|
|
SystemEndpoints.OUTSIDE_TEMPERATURE: 0.4,
|
|
SystemEndpoints.RELAY_CONFIGURATION_TYPE: "",
|
|
SystemEndpoints.RELAY_STATUS_TEXT: "Rele ei käytössä",
|
|
SystemEndpoints.L2_INSTALLED_STATUS: "1",
|
|
# L1 base
|
|
L1BaseEndpoints.OPERATION_MODE: OperationMode.AUTOMATIC,
|
|
L1BaseEndpoints.VALVE_POSITION_SETPOINT: 0.0,
|
|
L1BaseEndpoints.WATER_OUT_MIN_TEMP: 12.0,
|
|
L1BaseEndpoints.WATER_OUT_MAX_TEMP: 75.0,
|
|
L1BaseEndpoints.TEMPERATURE_LEVEL_STATUS_TEXT: "L1 Normaalilämpö",
|
|
L1BaseEndpoints.CIRCUIT_NAME: "Patterilämmitys",
|
|
L1BaseEndpoints.SUPPLY_WATER_TEMPERATURE: 39.1,
|
|
L1BaseEndpoints.VALVE_POSITION: 11.0,
|
|
L1BaseEndpoints.CURVE_SUPPLY_WATER_TEMPERATURE: 41.0,
|
|
L1BaseEndpoints.FINE_ADJUSTMENT_EFFECT: 0.0,
|
|
L1BaseEndpoints.SUPPLY_WATER_TEMPERATURE_SETPOINT: 43.7,
|
|
L1BaseEndpoints.ROOM_SENSOR_INSTALLED: "off",
|
|
# L1 three-point curve
|
|
L1ThreePointCurve.CURVE_MINUS_20_TEMP: 58.0,
|
|
L1ThreePointCurve.CURVE_0_TEMP: 41.0,
|
|
L1ThreePointCurve.CURVE_20_TEMP: 18.0,
|
|
# L1 five-point curve
|
|
L1FivePointCurve.CURVE_MINUS_20_TEMP: 58.0,
|
|
L1FivePointCurve.CURVE_MINUS_10_TEMP: 50.0,
|
|
L1FivePointCurve.CURVE_0_TEMP: 41.0,
|
|
L1FivePointCurve.CURVE_10_TEMP: 30.0,
|
|
L1FivePointCurve.CURVE_20_TEMP: 18.0,
|
|
# L1 no room sensor
|
|
L1NoRoomSensor.TEMPERATURE_DROP: 6.0,
|
|
L1NoRoomSensor.BIG_TEMPERATURE_DROP: 16.0,
|
|
L1NoRoomSensor.ROOM_TEMPERATURE_FINE_TUNING: 0.0,
|
|
# L1 room sensor
|
|
L1RoomSensor.TEMPERATURE_DROP: 1.0,
|
|
L1RoomSensor.BIG_TEMPERATURE_DROP: 3.0,
|
|
L1RoomSensor.ROOM_TEMPERATURE_FINE_TUNING: 0.0,
|
|
L1RoomSensor.ROOM_TEMPERATURE_SETPOINT_USER: 21.0,
|
|
L1RoomSensor.ROOM_SENSOR_POTENTIOMETER: 0.0,
|
|
L1RoomSensor.ROOM_TEMPERATURE: 21.5,
|
|
L1RoomSensor.DELAYED_ROOM_TEMPERATURE: 21.4,
|
|
L1RoomSensor.ROOM_TEMPERATURE_SETPOINT: 21.0,
|
|
# L1 constant temp mode
|
|
L1ConstantTempMode.CONSTANT_TEMP_SETPOINT: 50.0,
|
|
# L2 base
|
|
L2BaseEndpoints.OPERATION_MODE: OperationMode.AUTOMATIC,
|
|
L2BaseEndpoints.VALVE_POSITION_SETPOINT: 0.0,
|
|
L2BaseEndpoints.WATER_OUT_MIN_TEMP: 12.0,
|
|
L2BaseEndpoints.WATER_OUT_MAX_TEMP: 75.0,
|
|
L2BaseEndpoints.TEMPERATURE_LEVEL_STATUS_TEXT: "L2 Normaalilämpö",
|
|
L2BaseEndpoints.CIRCUIT_NAME: "Lattialämmitys",
|
|
L2BaseEndpoints.SUPPLY_WATER_TEMPERATURE: 30.0,
|
|
L2BaseEndpoints.VALVE_POSITION: 5.0,
|
|
L2BaseEndpoints.CURVE_SUPPLY_WATER_TEMPERATURE: 30.0,
|
|
L2BaseEndpoints.DELAYED_OUTDOOR_TEMPERATURE_EFFECT: 0.0,
|
|
L2BaseEndpoints.SUPPLY_WATER_TEMPERATURE_SETPOINT: 30.0,
|
|
L2BaseEndpoints.ROOM_SENSOR_INSTALLED: "on",
|
|
# L2 three-point curve
|
|
L2ThreePointCurve.CURVE_MINUS_20_TEMP: 40.0,
|
|
L2ThreePointCurve.CURVE_0_TEMP: 28.0,
|
|
L2ThreePointCurve.CURVE_20_TEMP: 22.0,
|
|
# L2 five-point curve
|
|
L2FivePointCurve.CURVE_MINUS_20_TEMP: 40.0,
|
|
L2FivePointCurve.CURVE_MINUS_10_TEMP: 35.0,
|
|
L2FivePointCurve.CURVE_0_TEMP: 28.0,
|
|
L2FivePointCurve.CURVE_10_TEMP: 25.0,
|
|
L2FivePointCurve.CURVE_20_TEMP: 22.0,
|
|
# L2 no room sensor
|
|
L2NoRoomSensor.TEMPERATURE_DROP: 6.0,
|
|
L2NoRoomSensor.BIG_TEMPERATURE_DROP: 16.0,
|
|
L2NoRoomSensor.ROOM_TEMPERATURE_FINE_TUNING: 0.0,
|
|
# L2 room sensor
|
|
L2RoomSensor.TEMPERATURE_DROP: 1.0,
|
|
L2RoomSensor.BIG_TEMPERATURE_DROP: 3.0,
|
|
L2RoomSensor.ROOM_TEMPERATURE_FINE_TUNING: 0.0,
|
|
L2RoomSensor.ROOM_TEMPERATURE_SETPOINT_USER: 21.0,
|
|
L2RoomSensor.ROOM_TEMPERATURE: 22.0,
|
|
L2RoomSensor.DELAYED_ROOM_TEMPERATURE: 21.9,
|
|
L2RoomSensor.ROOM_TEMPERATURE_SETPOINT: 21.0,
|
|
# Relay variants (mutually exclusive — at most one per scenario)
|
|
RelayPumpSummerStop.CONTROL: PumpSummerStopControl.AUTO,
|
|
RelayTemperature.CONTROL: RelayControl.AUTO,
|
|
RelayTempDifference.CONTROL: RelayControl.AUTO,
|
|
RelayL1ValvePosition.CONTROL: RelayControl.AUTO,
|
|
RelayTimeProgram.CONTROL: RelayControl.AUTO,
|
|
}
|
|
|
|
# Each scenario is a valid registry set the device may expose. Together they
|
|
# cover every endpoint the API can return — both curve types, both room-sensor
|
|
# variants on each channel, the additive ConstantTempMode, and all 5 relay
|
|
# variants.
|
|
SCENARIOS: dict[str, list[type[OumanRegistry]]] = {
|
|
# Realistic combinations
|
|
"room_sensors": [
|
|
SystemEndpoints,
|
|
L1BaseEndpoints,
|
|
L1ThreePointCurve,
|
|
L1RoomSensor,
|
|
L1ConstantTempMode,
|
|
L2BaseEndpoints,
|
|
L2ThreePointCurve,
|
|
L2RoomSensor,
|
|
],
|
|
"no_room_sensors": [
|
|
SystemEndpoints,
|
|
L1BaseEndpoints,
|
|
L1FivePointCurve,
|
|
L1NoRoomSensor,
|
|
L2BaseEndpoints,
|
|
L2FivePointCurve,
|
|
L2NoRoomSensor,
|
|
],
|
|
"l1_constant_temp_relay_summer_stop": [
|
|
SystemEndpoints,
|
|
L1BaseEndpoints,
|
|
L1ThreePointCurve,
|
|
L1NoRoomSensor,
|
|
L1ConstantTempMode,
|
|
RelayPumpSummerStop,
|
|
],
|
|
# Minimal scenarios that wouldn't occur on a real device but test
|
|
# each remaining Relay* registry so every endpoint that the API can
|
|
# return is seen by the integration at least once. They're trimmed
|
|
# to just SystemEndpoints + the relay because a fuller registry set
|
|
# adds no additional coverage here and would only bloat the snapshots.
|
|
"relay_valve_position": [SystemEndpoints, RelayL1ValvePosition],
|
|
"relay_temperature": [SystemEndpoints, RelayTemperature],
|
|
"relay_temp_difference": [SystemEndpoints, RelayTempDifference],
|
|
"relay_time_program": [SystemEndpoints, RelayTimeProgram],
|
|
}
|
|
|
|
_DEFAULT_SCENARIO = "room_sensors"
|
|
|
|
|
|
@pytest.fixture
|
|
def mock_setup_entry() -> Generator[AsyncMock]:
|
|
"""Override async_setup_entry."""
|
|
with patch(
|
|
"homeassistant.components.ouman_eh_800.async_setup_entry", return_value=True
|
|
) as mock_setup_entry:
|
|
yield mock_setup_entry
|
|
|
|
|
|
@pytest.fixture
|
|
def mock_config_entry() -> MockConfigEntry:
|
|
"""Return the default mocked config entry."""
|
|
return MockConfigEntry(
|
|
entry_id="01JABCDEFGHIJKLMNOPQRSTUVW",
|
|
domain=DOMAIN,
|
|
title="Ouman EH-800",
|
|
data={
|
|
CONF_URL: TEST_URL,
|
|
CONF_USERNAME: TEST_USERNAME,
|
|
CONF_PASSWORD: TEST_PASSWORD,
|
|
},
|
|
)
|
|
|
|
|
|
@pytest.fixture(params=[_DEFAULT_SCENARIO])
|
|
def scenario(request: pytest.FixtureRequest) -> str:
|
|
"""Scenario id; defaults to ``room_sensors`` unless overridden via parametrize."""
|
|
return request.param
|
|
|
|
|
|
@pytest.fixture
|
|
def registry_set(scenario: str) -> OumanRegistrySet:
|
|
"""The registry set the mocked device exposes for the active scenario."""
|
|
return OumanRegistrySet(registries=SCENARIOS[scenario])
|
|
|
|
|
|
@pytest.fixture
|
|
def mock_ouman_client(registry_set: OumanRegistrySet) -> Generator[AsyncMock]:
|
|
"""Mock the Ouman EH-800 client for the active scenario."""
|
|
values = {
|
|
endpoint: _ENDPOINT_VALUES[endpoint] for endpoint in registry_set.endpoints
|
|
}
|
|
with (
|
|
patch(
|
|
"homeassistant.components.ouman_eh_800.coordinator.OumanEh800Client",
|
|
autospec=True,
|
|
) as mock_client,
|
|
patch(
|
|
"homeassistant.components.ouman_eh_800.config_flow.OumanEh800Client",
|
|
new=mock_client,
|
|
),
|
|
):
|
|
client = mock_client.return_value
|
|
client.get_active_registries.return_value = registry_set
|
|
client.get_values.return_value = values
|
|
|
|
# Simulate the device: a successful write changes what subsequent
|
|
# reads return, so the coordinator's post-write refresh keeps the
|
|
# new value instead of reverting. The API library parses numeric
|
|
# responses as floats via ``NumberOumanEndpoint.parse_value``, so
|
|
# we mirror that here so int writes round-trip as floats. Tests can
|
|
# override by replacing ``set_endpoint_value.side_effect``.
|
|
def _set_endpoint_value(
|
|
endpoint: OumanEndpoint, value: OumanValues
|
|
) -> OumanValues:
|
|
stored: OumanValues = float(value) if isinstance(value, int) else value
|
|
values[endpoint] = stored
|
|
return stored
|
|
|
|
client.set_endpoint_value.side_effect = _set_endpoint_value
|
|
yield client
|
|
|
|
|
|
@pytest.fixture
|
|
async def init_integration(
|
|
hass: HomeAssistant,
|
|
mock_config_entry: MockConfigEntry,
|
|
mock_ouman_client: AsyncMock,
|
|
request: pytest.FixtureRequest,
|
|
) -> MockConfigEntry:
|
|
"""Set up the Ouman EH-800 integration for testing."""
|
|
mock_config_entry.add_to_hass(hass)
|
|
|
|
context = nullcontext()
|
|
if platform := getattr(request, "param", None):
|
|
context = patch("homeassistant.components.ouman_eh_800._PLATFORMS", [platform])
|
|
|
|
with context:
|
|
await hass.config_entries.async_setup(mock_config_entry.entry_id)
|
|
await hass.async_block_till_done()
|
|
|
|
return mock_config_entry
|