mirror of
https://github.com/home-assistant/core.git
synced 2026-04-02 08:26:41 +01:00
207 lines
9.0 KiB
Python
207 lines
9.0 KiB
Python
"""Provides triggers for air quality."""
|
|
|
|
from homeassistant.components.binary_sensor import (
|
|
DOMAIN as BINARY_SENSOR_DOMAIN,
|
|
BinarySensorDeviceClass,
|
|
)
|
|
from homeassistant.components.sensor import DOMAIN as SENSOR_DOMAIN, SensorDeviceClass
|
|
from homeassistant.const import (
|
|
CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
|
|
CONCENTRATION_PARTS_PER_BILLION,
|
|
CONCENTRATION_PARTS_PER_MILLION,
|
|
STATE_OFF,
|
|
STATE_ON,
|
|
)
|
|
from homeassistant.core import HomeAssistant
|
|
from homeassistant.helpers.automation import DomainSpec
|
|
from homeassistant.helpers.trigger import (
|
|
EntityTargetStateTriggerBase,
|
|
Trigger,
|
|
make_entity_numerical_state_changed_trigger,
|
|
make_entity_numerical_state_changed_with_unit_trigger,
|
|
make_entity_numerical_state_crossed_threshold_trigger,
|
|
make_entity_numerical_state_crossed_threshold_with_unit_trigger,
|
|
make_entity_target_state_trigger,
|
|
)
|
|
from homeassistant.util.unit_conversion import (
|
|
CarbonMonoxideConcentrationConverter,
|
|
MassVolumeConcentrationConverter,
|
|
NitrogenDioxideConcentrationConverter,
|
|
NitrogenMonoxideConcentrationConverter,
|
|
OzoneConcentrationConverter,
|
|
SulphurDioxideConcentrationConverter,
|
|
UnitlessRatioConverter,
|
|
)
|
|
|
|
|
|
def _make_detected_trigger(
|
|
device_class: BinarySensorDeviceClass,
|
|
) -> type[EntityTargetStateTriggerBase]:
|
|
"""Create a detected trigger for a binary sensor device class."""
|
|
|
|
return make_entity_target_state_trigger(
|
|
{BINARY_SENSOR_DOMAIN: DomainSpec(device_class=device_class)}, STATE_ON
|
|
)
|
|
|
|
|
|
def _make_cleared_trigger(
|
|
device_class: BinarySensorDeviceClass,
|
|
) -> type[EntityTargetStateTriggerBase]:
|
|
"""Create a cleared trigger for a binary sensor device class."""
|
|
|
|
return make_entity_target_state_trigger(
|
|
{BINARY_SENSOR_DOMAIN: DomainSpec(device_class=device_class)}, STATE_OFF
|
|
)
|
|
|
|
|
|
TRIGGERS: dict[str, type[Trigger]] = {
|
|
# Binary sensor triggers (detected/cleared)
|
|
"gas_detected": _make_detected_trigger(BinarySensorDeviceClass.GAS),
|
|
"gas_cleared": _make_cleared_trigger(BinarySensorDeviceClass.GAS),
|
|
"co_detected": _make_detected_trigger(BinarySensorDeviceClass.CO),
|
|
"co_cleared": _make_cleared_trigger(BinarySensorDeviceClass.CO),
|
|
"smoke_detected": _make_detected_trigger(BinarySensorDeviceClass.SMOKE),
|
|
"smoke_cleared": _make_cleared_trigger(BinarySensorDeviceClass.SMOKE),
|
|
# Numerical sensor triggers with unit conversion
|
|
"co_changed": make_entity_numerical_state_changed_with_unit_trigger(
|
|
{SENSOR_DOMAIN: DomainSpec(device_class=SensorDeviceClass.CO)},
|
|
CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
|
|
CarbonMonoxideConcentrationConverter,
|
|
),
|
|
"co_crossed_threshold": make_entity_numerical_state_crossed_threshold_with_unit_trigger(
|
|
{SENSOR_DOMAIN: DomainSpec(device_class=SensorDeviceClass.CO)},
|
|
CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
|
|
CarbonMonoxideConcentrationConverter,
|
|
),
|
|
"ozone_changed": make_entity_numerical_state_changed_with_unit_trigger(
|
|
{SENSOR_DOMAIN: DomainSpec(device_class=SensorDeviceClass.OZONE)},
|
|
CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
|
|
OzoneConcentrationConverter,
|
|
),
|
|
"ozone_crossed_threshold": make_entity_numerical_state_crossed_threshold_with_unit_trigger(
|
|
{SENSOR_DOMAIN: DomainSpec(device_class=SensorDeviceClass.OZONE)},
|
|
CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
|
|
OzoneConcentrationConverter,
|
|
),
|
|
"voc_changed": make_entity_numerical_state_changed_with_unit_trigger(
|
|
{
|
|
SENSOR_DOMAIN: DomainSpec(
|
|
device_class=SensorDeviceClass.VOLATILE_ORGANIC_COMPOUNDS
|
|
)
|
|
},
|
|
CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
|
|
MassVolumeConcentrationConverter,
|
|
),
|
|
"voc_crossed_threshold": make_entity_numerical_state_crossed_threshold_with_unit_trigger(
|
|
{
|
|
SENSOR_DOMAIN: DomainSpec(
|
|
device_class=SensorDeviceClass.VOLATILE_ORGANIC_COMPOUNDS
|
|
)
|
|
},
|
|
CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
|
|
MassVolumeConcentrationConverter,
|
|
),
|
|
"voc_ratio_changed": make_entity_numerical_state_changed_with_unit_trigger(
|
|
{
|
|
SENSOR_DOMAIN: DomainSpec(
|
|
device_class=SensorDeviceClass.VOLATILE_ORGANIC_COMPOUNDS_PARTS
|
|
)
|
|
},
|
|
CONCENTRATION_PARTS_PER_BILLION,
|
|
UnitlessRatioConverter,
|
|
),
|
|
"voc_ratio_crossed_threshold": make_entity_numerical_state_crossed_threshold_with_unit_trigger(
|
|
{
|
|
SENSOR_DOMAIN: DomainSpec(
|
|
device_class=SensorDeviceClass.VOLATILE_ORGANIC_COMPOUNDS_PARTS
|
|
)
|
|
},
|
|
CONCENTRATION_PARTS_PER_BILLION,
|
|
UnitlessRatioConverter,
|
|
),
|
|
"no_changed": make_entity_numerical_state_changed_with_unit_trigger(
|
|
{SENSOR_DOMAIN: DomainSpec(device_class=SensorDeviceClass.NITROGEN_MONOXIDE)},
|
|
CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
|
|
NitrogenMonoxideConcentrationConverter,
|
|
),
|
|
"no_crossed_threshold": make_entity_numerical_state_crossed_threshold_with_unit_trigger(
|
|
{SENSOR_DOMAIN: DomainSpec(device_class=SensorDeviceClass.NITROGEN_MONOXIDE)},
|
|
CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
|
|
NitrogenMonoxideConcentrationConverter,
|
|
),
|
|
"no2_changed": make_entity_numerical_state_changed_with_unit_trigger(
|
|
{SENSOR_DOMAIN: DomainSpec(device_class=SensorDeviceClass.NITROGEN_DIOXIDE)},
|
|
CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
|
|
NitrogenDioxideConcentrationConverter,
|
|
),
|
|
"no2_crossed_threshold": make_entity_numerical_state_crossed_threshold_with_unit_trigger(
|
|
{SENSOR_DOMAIN: DomainSpec(device_class=SensorDeviceClass.NITROGEN_DIOXIDE)},
|
|
CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
|
|
NitrogenDioxideConcentrationConverter,
|
|
),
|
|
"so2_changed": make_entity_numerical_state_changed_with_unit_trigger(
|
|
{SENSOR_DOMAIN: DomainSpec(device_class=SensorDeviceClass.SULPHUR_DIOXIDE)},
|
|
CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
|
|
SulphurDioxideConcentrationConverter,
|
|
),
|
|
"so2_crossed_threshold": make_entity_numerical_state_crossed_threshold_with_unit_trigger(
|
|
{SENSOR_DOMAIN: DomainSpec(device_class=SensorDeviceClass.SULPHUR_DIOXIDE)},
|
|
CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
|
|
SulphurDioxideConcentrationConverter,
|
|
),
|
|
# Numerical sensor triggers without unit conversion (single-unit device classes)
|
|
"co2_changed": make_entity_numerical_state_changed_trigger(
|
|
{SENSOR_DOMAIN: DomainSpec(device_class=SensorDeviceClass.CO2)},
|
|
valid_unit=CONCENTRATION_PARTS_PER_MILLION,
|
|
),
|
|
"co2_crossed_threshold": make_entity_numerical_state_crossed_threshold_trigger(
|
|
{SENSOR_DOMAIN: DomainSpec(device_class=SensorDeviceClass.CO2)},
|
|
valid_unit=CONCENTRATION_PARTS_PER_MILLION,
|
|
),
|
|
"pm1_changed": make_entity_numerical_state_changed_trigger(
|
|
{SENSOR_DOMAIN: DomainSpec(device_class=SensorDeviceClass.PM1)},
|
|
valid_unit=CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
|
|
),
|
|
"pm1_crossed_threshold": make_entity_numerical_state_crossed_threshold_trigger(
|
|
{SENSOR_DOMAIN: DomainSpec(device_class=SensorDeviceClass.PM1)},
|
|
valid_unit=CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
|
|
),
|
|
"pm25_changed": make_entity_numerical_state_changed_trigger(
|
|
{SENSOR_DOMAIN: DomainSpec(device_class=SensorDeviceClass.PM25)},
|
|
valid_unit=CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
|
|
),
|
|
"pm25_crossed_threshold": make_entity_numerical_state_crossed_threshold_trigger(
|
|
{SENSOR_DOMAIN: DomainSpec(device_class=SensorDeviceClass.PM25)},
|
|
valid_unit=CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
|
|
),
|
|
"pm4_changed": make_entity_numerical_state_changed_trigger(
|
|
{SENSOR_DOMAIN: DomainSpec(device_class=SensorDeviceClass.PM4)},
|
|
valid_unit=CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
|
|
),
|
|
"pm4_crossed_threshold": make_entity_numerical_state_crossed_threshold_trigger(
|
|
{SENSOR_DOMAIN: DomainSpec(device_class=SensorDeviceClass.PM4)},
|
|
valid_unit=CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
|
|
),
|
|
"pm10_changed": make_entity_numerical_state_changed_trigger(
|
|
{SENSOR_DOMAIN: DomainSpec(device_class=SensorDeviceClass.PM10)},
|
|
valid_unit=CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
|
|
),
|
|
"pm10_crossed_threshold": make_entity_numerical_state_crossed_threshold_trigger(
|
|
{SENSOR_DOMAIN: DomainSpec(device_class=SensorDeviceClass.PM10)},
|
|
valid_unit=CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
|
|
),
|
|
"n2o_changed": make_entity_numerical_state_changed_trigger(
|
|
{SENSOR_DOMAIN: DomainSpec(device_class=SensorDeviceClass.NITROUS_OXIDE)},
|
|
valid_unit=CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
|
|
),
|
|
"n2o_crossed_threshold": make_entity_numerical_state_crossed_threshold_trigger(
|
|
{SENSOR_DOMAIN: DomainSpec(device_class=SensorDeviceClass.NITROUS_OXIDE)},
|
|
valid_unit=CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
|
|
),
|
|
}
|
|
|
|
|
|
async def async_get_triggers(hass: HomeAssistant) -> dict[str, type[Trigger]]:
|
|
"""Return the triggers for air quality."""
|
|
return TRIGGERS
|