"""Helpers for the Energy integration."""
|
|
|
|
from __future__ import annotations
|
|
|
|
from typing import TYPE_CHECKING
|
|
|
|
if TYPE_CHECKING:
|
|
from .data import PowerConfig
|
|
|
|
|
|
def generate_power_sensor_unique_id(source_type: str, config: PowerConfig) -> str:
|
|
"""Generate a unique ID for a power transform sensor."""
|
|
if "stat_rate_inverted" in config:
|
|
sensor_id = config["stat_rate_inverted"].replace(".", "_")
|
|
return f"energy_power_{source_type}_inverted_{sensor_id}"
|
|
if "stat_rate_from" in config and "stat_rate_to" in config:
|
|
from_id = config["stat_rate_from"].replace(".", "_")
|
|
to_id = config["stat_rate_to"].replace(".", "_")
|
|
return f"energy_power_{source_type}_combined_{from_id}_{to_id}"
|
|
# This case is impossible: schema validation (vol.Inclusive) ensures
|
|
# stat_rate_from and stat_rate_to are always present together
|
|
raise RuntimeError("Invalid power config: missing required keys")
|
|
|
|
|
|
def generate_power_sensor_entity_id(source_type: str, config: PowerConfig) -> str:
|
|
"""Generate an entity ID for a power transform sensor."""
|
|
if "stat_rate_inverted" in config:
|
|
# Use source sensor name with _inverted suffix
|
|
source = config["stat_rate_inverted"]
|
|
if source.startswith("sensor."):
|
|
return f"{source}_inverted"
|
|
return f"sensor.{source.replace('.', '_')}_inverted"
|
|
if "stat_rate_from" in config and "stat_rate_to" in config:
|
|
# Use both sensors in entity ID to ensure uniqueness when multiple
|
|
# combined configs exist. The entity represents net power (from - to),
|
|
# e.g., discharge - charge for battery.
|
|
from_sensor = config["stat_rate_from"].removeprefix("sensor.")
|
|
to_sensor = config["stat_rate_to"].removeprefix("sensor.")
|
|
return f"sensor.energy_{source_type}_{from_sensor}_{to_sensor}_net_power"
|
|
# This case is impossible: schema validation (vol.Inclusive) ensures
|
|
# stat_rate_from and stat_rate_to are always present together
|
|
raise RuntimeError("Invalid power config: missing required keys")
|