Add Matter Electrical measurements additional attributes (#150188)
Co-authored-by: Martin Hjelmare <marhje52@gmail.com>
This commit is contained in:
co-authored by
Martin Hjelmare
parent
d9b6f82639
commit
2248584a0f
@@ -32,11 +32,13 @@ from homeassistant.const import (
|
||||
REVOLUTIONS_PER_MINUTE,
|
||||
EntityCategory,
|
||||
Platform,
|
||||
UnitOfApparentPower,
|
||||
UnitOfElectricCurrent,
|
||||
UnitOfElectricPotential,
|
||||
UnitOfEnergy,
|
||||
UnitOfPower,
|
||||
UnitOfPressure,
|
||||
UnitOfReactivePower,
|
||||
UnitOfTemperature,
|
||||
UnitOfTime,
|
||||
UnitOfVolume,
|
||||
@@ -782,10 +784,43 @@ DISCOVERY_SCHEMAS = [
|
||||
clusters.ElectricalPowerMeasurement.Attributes.ActivePower,
|
||||
),
|
||||
),
|
||||
MatterDiscoverySchema(
|
||||
platform=Platform.SENSOR,
|
||||
entity_description=MatterSensorEntityDescription(
|
||||
key="ElectricalPowerMeasurementApparentPower",
|
||||
device_class=SensorDeviceClass.APPARENT_POWER,
|
||||
entity_category=EntityCategory.DIAGNOSTIC,
|
||||
native_unit_of_measurement=UnitOfApparentPower.MILLIVOLT_AMPERE,
|
||||
suggested_unit_of_measurement=UnitOfApparentPower.VOLT_AMPERE,
|
||||
suggested_display_precision=2,
|
||||
state_class=SensorStateClass.MEASUREMENT,
|
||||
),
|
||||
entity_class=MatterSensor,
|
||||
required_attributes=(
|
||||
clusters.ElectricalPowerMeasurement.Attributes.ApparentPower,
|
||||
),
|
||||
),
|
||||
MatterDiscoverySchema(
|
||||
platform=Platform.SENSOR,
|
||||
entity_description=MatterSensorEntityDescription(
|
||||
key="ElectricalPowerMeasurementReactivePower",
|
||||
device_class=SensorDeviceClass.REACTIVE_POWER,
|
||||
entity_category=EntityCategory.DIAGNOSTIC,
|
||||
native_unit_of_measurement=UnitOfReactivePower.MILLIVOLT_AMPERE_REACTIVE,
|
||||
suggested_unit_of_measurement=UnitOfReactivePower.VOLT_AMPERE_REACTIVE,
|
||||
suggested_display_precision=2,
|
||||
state_class=SensorStateClass.MEASUREMENT,
|
||||
),
|
||||
entity_class=MatterSensor,
|
||||
required_attributes=(
|
||||
clusters.ElectricalPowerMeasurement.Attributes.ReactivePower,
|
||||
),
|
||||
),
|
||||
MatterDiscoverySchema(
|
||||
platform=Platform.SENSOR,
|
||||
entity_description=MatterSensorEntityDescription(
|
||||
key="ElectricalPowerMeasurementVoltage",
|
||||
translation_key="voltage",
|
||||
device_class=SensorDeviceClass.VOLTAGE,
|
||||
entity_category=EntityCategory.DIAGNOSTIC,
|
||||
native_unit_of_measurement=UnitOfElectricPotential.MILLIVOLT,
|
||||
@@ -796,10 +831,45 @@ DISCOVERY_SCHEMAS = [
|
||||
entity_class=MatterSensor,
|
||||
required_attributes=(clusters.ElectricalPowerMeasurement.Attributes.Voltage,),
|
||||
),
|
||||
MatterDiscoverySchema(
|
||||
platform=Platform.SENSOR,
|
||||
entity_description=MatterSensorEntityDescription(
|
||||
key="ElectricalPowerMeasurementRMSVoltage",
|
||||
translation_key="rms_voltage",
|
||||
device_class=SensorDeviceClass.VOLTAGE,
|
||||
entity_category=EntityCategory.DIAGNOSTIC,
|
||||
native_unit_of_measurement=UnitOfElectricPotential.MILLIVOLT,
|
||||
suggested_unit_of_measurement=UnitOfElectricPotential.VOLT,
|
||||
suggested_display_precision=0,
|
||||
state_class=SensorStateClass.MEASUREMENT,
|
||||
),
|
||||
entity_class=MatterSensor,
|
||||
required_attributes=(
|
||||
clusters.ElectricalPowerMeasurement.Attributes.RMSVoltage,
|
||||
),
|
||||
),
|
||||
MatterDiscoverySchema(
|
||||
platform=Platform.SENSOR,
|
||||
entity_description=MatterSensorEntityDescription(
|
||||
key="ElectricalPowerMeasurementApparentCurrent",
|
||||
translation_key="apparent_current",
|
||||
device_class=SensorDeviceClass.CURRENT,
|
||||
entity_category=EntityCategory.DIAGNOSTIC,
|
||||
native_unit_of_measurement=UnitOfElectricCurrent.MILLIAMPERE,
|
||||
suggested_unit_of_measurement=UnitOfElectricCurrent.AMPERE,
|
||||
suggested_display_precision=2,
|
||||
state_class=SensorStateClass.MEASUREMENT,
|
||||
),
|
||||
entity_class=MatterSensor,
|
||||
required_attributes=(
|
||||
clusters.ElectricalPowerMeasurement.Attributes.ApparentCurrent,
|
||||
),
|
||||
),
|
||||
MatterDiscoverySchema(
|
||||
platform=Platform.SENSOR,
|
||||
entity_description=MatterSensorEntityDescription(
|
||||
key="ElectricalPowerMeasurementActiveCurrent",
|
||||
translation_key="active_current",
|
||||
device_class=SensorDeviceClass.CURRENT,
|
||||
entity_category=EntityCategory.DIAGNOSTIC,
|
||||
native_unit_of_measurement=UnitOfElectricCurrent.MILLIAMPERE,
|
||||
@@ -812,6 +882,40 @@ DISCOVERY_SCHEMAS = [
|
||||
clusters.ElectricalPowerMeasurement.Attributes.ActiveCurrent,
|
||||
),
|
||||
),
|
||||
MatterDiscoverySchema(
|
||||
platform=Platform.SENSOR,
|
||||
entity_description=MatterSensorEntityDescription(
|
||||
key="ElectricalPowerMeasurementReactiveCurrent",
|
||||
translation_key="reactive_current",
|
||||
device_class=SensorDeviceClass.CURRENT,
|
||||
entity_category=EntityCategory.DIAGNOSTIC,
|
||||
native_unit_of_measurement=UnitOfElectricCurrent.MILLIAMPERE,
|
||||
suggested_unit_of_measurement=UnitOfElectricCurrent.AMPERE,
|
||||
suggested_display_precision=2,
|
||||
state_class=SensorStateClass.MEASUREMENT,
|
||||
),
|
||||
entity_class=MatterSensor,
|
||||
required_attributes=(
|
||||
clusters.ElectricalPowerMeasurement.Attributes.ReactiveCurrent,
|
||||
),
|
||||
),
|
||||
MatterDiscoverySchema(
|
||||
platform=Platform.SENSOR,
|
||||
entity_description=MatterSensorEntityDescription(
|
||||
key="ElectricalPowerMeasurementRMSCurrent",
|
||||
translation_key="rms_current",
|
||||
device_class=SensorDeviceClass.CURRENT,
|
||||
entity_category=EntityCategory.DIAGNOSTIC,
|
||||
native_unit_of_measurement=UnitOfElectricCurrent.MILLIAMPERE,
|
||||
suggested_unit_of_measurement=UnitOfElectricCurrent.AMPERE,
|
||||
suggested_display_precision=2,
|
||||
state_class=SensorStateClass.MEASUREMENT,
|
||||
),
|
||||
entity_class=MatterSensor,
|
||||
required_attributes=(
|
||||
clusters.ElectricalPowerMeasurement.Attributes.RMSCurrent,
|
||||
),
|
||||
),
|
||||
MatterDiscoverySchema(
|
||||
platform=Platform.SENSOR,
|
||||
entity_description=MatterSensorEntityDescription(
|
||||
|
||||
@@ -451,6 +451,24 @@
|
||||
},
|
||||
"window_covering_target_position": {
|
||||
"name": "Target opening position"
|
||||
},
|
||||
"active_current": {
|
||||
"name": "Active current"
|
||||
},
|
||||
"apparent_current": {
|
||||
"name": "Apparent current"
|
||||
},
|
||||
"reactive_current": {
|
||||
"name": "Reactive current"
|
||||
},
|
||||
"rms_current": {
|
||||
"name": "Effective current"
|
||||
},
|
||||
"rms_voltage": {
|
||||
"name": "Effective voltage"
|
||||
},
|
||||
"voltage": {
|
||||
"name": "Voltage"
|
||||
}
|
||||
},
|
||||
"switch": {
|
||||
|
||||
@@ -588,31 +588,9 @@
|
||||
"10": 101
|
||||
}
|
||||
],
|
||||
"2/144/4": 120000,
|
||||
"2/144/5": 0,
|
||||
"2/144/6": 0,
|
||||
"2/144/7": 0,
|
||||
"2/144/8": 0,
|
||||
"2/144/9": 0,
|
||||
"2/144/10": 0,
|
||||
"2/144/11": 120000,
|
||||
"2/144/12": 0,
|
||||
"2/144/13": 0,
|
||||
"2/144/14": 60,
|
||||
"2/144/15": [
|
||||
{
|
||||
"0": 1,
|
||||
"1": 100000
|
||||
}
|
||||
],
|
||||
"2/144/16": [
|
||||
{
|
||||
"0": 1,
|
||||
"1": 100000
|
||||
}
|
||||
],
|
||||
"2/144/17": 9800,
|
||||
"2/144/18": 0,
|
||||
"2/144/65532": 31,
|
||||
"2/144/65533": 1,
|
||||
"2/144/65528": [],
|
||||
|
||||
@@ -832,31 +832,9 @@
|
||||
"10": 129
|
||||
}
|
||||
],
|
||||
"2/144/4": 120000,
|
||||
"2/144/5": 0,
|
||||
"2/144/6": 0,
|
||||
"2/144/7": 0,
|
||||
"2/144/8": 0,
|
||||
"2/144/9": 0,
|
||||
"2/144/10": 0,
|
||||
"2/144/11": 120000,
|
||||
"2/144/12": 0,
|
||||
"2/144/13": 0,
|
||||
"2/144/14": 60,
|
||||
"2/144/15": [
|
||||
{
|
||||
"0": 1,
|
||||
"1": 100000
|
||||
}
|
||||
],
|
||||
"2/144/16": [
|
||||
{
|
||||
"0": 1,
|
||||
"1": 100000
|
||||
}
|
||||
],
|
||||
"2/144/17": 9800,
|
||||
"2/144/18": 0,
|
||||
"2/144/65532": 31,
|
||||
"2/144/65533": 1,
|
||||
"2/144/65528": [],
|
||||
|
||||
@@ -1251,6 +1251,65 @@
|
||||
'state': '189.0',
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[battery_storage][sensor.mock_battery_storage_active_current-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
}),
|
||||
'area_id': None,
|
||||
'capabilities': dict({
|
||||
'state_class': <SensorStateClass.MEASUREMENT: 'measurement'>,
|
||||
}),
|
||||
'config_entry_id': <ANY>,
|
||||
'config_subentry_id': <ANY>,
|
||||
'device_class': None,
|
||||
'device_id': <ANY>,
|
||||
'disabled_by': None,
|
||||
'domain': 'sensor',
|
||||
'entity_category': <EntityCategory.DIAGNOSTIC: 'diagnostic'>,
|
||||
'entity_id': 'sensor.mock_battery_storage_active_current',
|
||||
'has_entity_name': True,
|
||||
'hidden_by': None,
|
||||
'icon': None,
|
||||
'id': <ANY>,
|
||||
'labels': set({
|
||||
}),
|
||||
'name': None,
|
||||
'options': dict({
|
||||
'sensor': dict({
|
||||
'suggested_display_precision': 2,
|
||||
}),
|
||||
'sensor.private': dict({
|
||||
'suggested_unit_of_measurement': <UnitOfElectricCurrent.AMPERE: 'A'>,
|
||||
}),
|
||||
}),
|
||||
'original_device_class': <SensorDeviceClass.CURRENT: 'current'>,
|
||||
'original_icon': None,
|
||||
'original_name': 'Active current',
|
||||
'platform': 'matter',
|
||||
'previous_unique_id': None,
|
||||
'suggested_object_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': 'active_current',
|
||||
'unique_id': '00000000000004D2-0000000000000019-MatterNodeDevice-1-ElectricalPowerMeasurementActiveCurrent-144-5',
|
||||
'unit_of_measurement': <UnitOfElectricCurrent.AMPERE: 'A'>,
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[battery_storage][sensor.mock_battery_storage_active_current-state]
|
||||
StateSnapshot({
|
||||
'attributes': ReadOnlyDict({
|
||||
'device_class': 'current',
|
||||
'friendly_name': 'Mock Battery Storage Active current',
|
||||
'state_class': <SensorStateClass.MEASUREMENT: 'measurement'>,
|
||||
'unit_of_measurement': <UnitOfElectricCurrent.AMPERE: 'A'>,
|
||||
}),
|
||||
'context': <ANY>,
|
||||
'entity_id': 'sensor.mock_battery_storage_active_current',
|
||||
'last_changed': <ANY>,
|
||||
'last_reported': <ANY>,
|
||||
'last_updated': <ANY>,
|
||||
'state': '0.0',
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[battery_storage][sensor.mock_battery_storage_appliance_energy_state-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
@@ -1427,65 +1486,6 @@
|
||||
'state': '48.0',
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[battery_storage][sensor.mock_battery_storage_current-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
}),
|
||||
'area_id': None,
|
||||
'capabilities': dict({
|
||||
'state_class': <SensorStateClass.MEASUREMENT: 'measurement'>,
|
||||
}),
|
||||
'config_entry_id': <ANY>,
|
||||
'config_subentry_id': <ANY>,
|
||||
'device_class': None,
|
||||
'device_id': <ANY>,
|
||||
'disabled_by': None,
|
||||
'domain': 'sensor',
|
||||
'entity_category': <EntityCategory.DIAGNOSTIC: 'diagnostic'>,
|
||||
'entity_id': 'sensor.mock_battery_storage_current',
|
||||
'has_entity_name': True,
|
||||
'hidden_by': None,
|
||||
'icon': None,
|
||||
'id': <ANY>,
|
||||
'labels': set({
|
||||
}),
|
||||
'name': None,
|
||||
'options': dict({
|
||||
'sensor': dict({
|
||||
'suggested_display_precision': 2,
|
||||
}),
|
||||
'sensor.private': dict({
|
||||
'suggested_unit_of_measurement': <UnitOfElectricCurrent.AMPERE: 'A'>,
|
||||
}),
|
||||
}),
|
||||
'original_device_class': <SensorDeviceClass.CURRENT: 'current'>,
|
||||
'original_icon': None,
|
||||
'original_name': 'Current',
|
||||
'platform': 'matter',
|
||||
'previous_unique_id': None,
|
||||
'suggested_object_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': None,
|
||||
'unique_id': '00000000000004D2-0000000000000019-MatterNodeDevice-1-ElectricalPowerMeasurementActiveCurrent-144-5',
|
||||
'unit_of_measurement': <UnitOfElectricCurrent.AMPERE: 'A'>,
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[battery_storage][sensor.mock_battery_storage_current-state]
|
||||
StateSnapshot({
|
||||
'attributes': ReadOnlyDict({
|
||||
'device_class': 'current',
|
||||
'friendly_name': 'Mock Battery Storage Current',
|
||||
'state_class': <SensorStateClass.MEASUREMENT: 'measurement'>,
|
||||
'unit_of_measurement': <UnitOfElectricCurrent.AMPERE: 'A'>,
|
||||
}),
|
||||
'context': <ANY>,
|
||||
'entity_id': 'sensor.mock_battery_storage_current',
|
||||
'last_changed': <ANY>,
|
||||
'last_reported': <ANY>,
|
||||
'last_updated': <ANY>,
|
||||
'state': '0.0',
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[battery_storage][sensor.mock_battery_storage_energy_optimization_opt_out-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
@@ -1763,7 +1763,7 @@
|
||||
'previous_unique_id': None,
|
||||
'suggested_object_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': None,
|
||||
'translation_key': 'voltage',
|
||||
'unique_id': '00000000000004D2-0000000000000019-MatterNodeDevice-1-ElectricalPowerMeasurementVoltage-144-4',
|
||||
'unit_of_measurement': <UnitOfElectricPotential.VOLT: 'V'>,
|
||||
})
|
||||
@@ -2176,7 +2176,7 @@
|
||||
'state': '238.800003051758',
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[eve_energy_plug_patched][sensor.eve_energy_plug_patched_current-entry]
|
||||
# name: test_sensors[eve_energy_plug_patched][sensor.eve_energy_plug_patched_active_current-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
}),
|
||||
@@ -2191,7 +2191,7 @@
|
||||
'disabled_by': None,
|
||||
'domain': 'sensor',
|
||||
'entity_category': <EntityCategory.DIAGNOSTIC: 'diagnostic'>,
|
||||
'entity_id': 'sensor.eve_energy_plug_patched_current',
|
||||
'entity_id': 'sensor.eve_energy_plug_patched_active_current',
|
||||
'has_entity_name': True,
|
||||
'hidden_by': None,
|
||||
'icon': None,
|
||||
@@ -2209,26 +2209,26 @@
|
||||
}),
|
||||
'original_device_class': <SensorDeviceClass.CURRENT: 'current'>,
|
||||
'original_icon': None,
|
||||
'original_name': 'Current',
|
||||
'original_name': 'Active current',
|
||||
'platform': 'matter',
|
||||
'previous_unique_id': None,
|
||||
'suggested_object_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': None,
|
||||
'translation_key': 'active_current',
|
||||
'unique_id': '00000000000004D2-00000000000000B7-MatterNodeDevice-2-ElectricalPowerMeasurementActiveCurrent-144-5',
|
||||
'unit_of_measurement': <UnitOfElectricCurrent.AMPERE: 'A'>,
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[eve_energy_plug_patched][sensor.eve_energy_plug_patched_current-state]
|
||||
# name: test_sensors[eve_energy_plug_patched][sensor.eve_energy_plug_patched_active_current-state]
|
||||
StateSnapshot({
|
||||
'attributes': ReadOnlyDict({
|
||||
'device_class': 'current',
|
||||
'friendly_name': 'Eve Energy Plug Patched Current',
|
||||
'friendly_name': 'Eve Energy Plug Patched Active current',
|
||||
'state_class': <SensorStateClass.MEASUREMENT: 'measurement'>,
|
||||
'unit_of_measurement': <UnitOfElectricCurrent.AMPERE: 'A'>,
|
||||
}),
|
||||
'context': <ANY>,
|
||||
'entity_id': 'sensor.eve_energy_plug_patched_current',
|
||||
'entity_id': 'sensor.eve_energy_plug_patched_active_current',
|
||||
'last_changed': <ANY>,
|
||||
'last_reported': <ANY>,
|
||||
'last_updated': <ANY>,
|
||||
@@ -2391,7 +2391,7 @@
|
||||
'previous_unique_id': None,
|
||||
'suggested_object_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': None,
|
||||
'translation_key': 'voltage',
|
||||
'unique_id': '00000000000004D2-00000000000000B7-MatterNodeDevice-2-ElectricalPowerMeasurementVoltage-144-4',
|
||||
'unit_of_measurement': <UnitOfElectricPotential.VOLT: 'V'>,
|
||||
})
|
||||
@@ -4333,7 +4333,7 @@
|
||||
'state': '0.0',
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[silabs_dishwasher][sensor.dishwasher_current-entry]
|
||||
# name: test_sensors[silabs_dishwasher][sensor.dishwasher_effective_current-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
}),
|
||||
@@ -4348,7 +4348,7 @@
|
||||
'disabled_by': None,
|
||||
'domain': 'sensor',
|
||||
'entity_category': <EntityCategory.DIAGNOSTIC: 'diagnostic'>,
|
||||
'entity_id': 'sensor.dishwasher_current',
|
||||
'entity_id': 'sensor.dishwasher_effective_current',
|
||||
'has_entity_name': True,
|
||||
'hidden_by': None,
|
||||
'icon': None,
|
||||
@@ -4366,32 +4366,91 @@
|
||||
}),
|
||||
'original_device_class': <SensorDeviceClass.CURRENT: 'current'>,
|
||||
'original_icon': None,
|
||||
'original_name': 'Current',
|
||||
'original_name': 'Effective current',
|
||||
'platform': 'matter',
|
||||
'previous_unique_id': None,
|
||||
'suggested_object_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': None,
|
||||
'unique_id': '00000000000004D2-0000000000000036-MatterNodeDevice-2-ElectricalPowerMeasurementActiveCurrent-144-5',
|
||||
'translation_key': 'rms_current',
|
||||
'unique_id': '00000000000004D2-0000000000000036-MatterNodeDevice-2-ElectricalPowerMeasurementRMSCurrent-144-12',
|
||||
'unit_of_measurement': <UnitOfElectricCurrent.AMPERE: 'A'>,
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[silabs_dishwasher][sensor.dishwasher_current-state]
|
||||
# name: test_sensors[silabs_dishwasher][sensor.dishwasher_effective_current-state]
|
||||
StateSnapshot({
|
||||
'attributes': ReadOnlyDict({
|
||||
'device_class': 'current',
|
||||
'friendly_name': 'Dishwasher Current',
|
||||
'friendly_name': 'Dishwasher Effective current',
|
||||
'state_class': <SensorStateClass.MEASUREMENT: 'measurement'>,
|
||||
'unit_of_measurement': <UnitOfElectricCurrent.AMPERE: 'A'>,
|
||||
}),
|
||||
'context': <ANY>,
|
||||
'entity_id': 'sensor.dishwasher_current',
|
||||
'entity_id': 'sensor.dishwasher_effective_current',
|
||||
'last_changed': <ANY>,
|
||||
'last_reported': <ANY>,
|
||||
'last_updated': <ANY>,
|
||||
'state': '0.0',
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[silabs_dishwasher][sensor.dishwasher_effective_voltage-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
}),
|
||||
'area_id': None,
|
||||
'capabilities': dict({
|
||||
'state_class': <SensorStateClass.MEASUREMENT: 'measurement'>,
|
||||
}),
|
||||
'config_entry_id': <ANY>,
|
||||
'config_subentry_id': <ANY>,
|
||||
'device_class': None,
|
||||
'device_id': <ANY>,
|
||||
'disabled_by': None,
|
||||
'domain': 'sensor',
|
||||
'entity_category': <EntityCategory.DIAGNOSTIC: 'diagnostic'>,
|
||||
'entity_id': 'sensor.dishwasher_effective_voltage',
|
||||
'has_entity_name': True,
|
||||
'hidden_by': None,
|
||||
'icon': None,
|
||||
'id': <ANY>,
|
||||
'labels': set({
|
||||
}),
|
||||
'name': None,
|
||||
'options': dict({
|
||||
'sensor': dict({
|
||||
'suggested_display_precision': 0,
|
||||
}),
|
||||
'sensor.private': dict({
|
||||
'suggested_unit_of_measurement': <UnitOfElectricPotential.VOLT: 'V'>,
|
||||
}),
|
||||
}),
|
||||
'original_device_class': <SensorDeviceClass.VOLTAGE: 'voltage'>,
|
||||
'original_icon': None,
|
||||
'original_name': 'Effective voltage',
|
||||
'platform': 'matter',
|
||||
'previous_unique_id': None,
|
||||
'suggested_object_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': 'rms_voltage',
|
||||
'unique_id': '00000000000004D2-0000000000000036-MatterNodeDevice-2-ElectricalPowerMeasurementRMSVoltage-144-11',
|
||||
'unit_of_measurement': <UnitOfElectricPotential.VOLT: 'V'>,
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[silabs_dishwasher][sensor.dishwasher_effective_voltage-state]
|
||||
StateSnapshot({
|
||||
'attributes': ReadOnlyDict({
|
||||
'device_class': 'voltage',
|
||||
'friendly_name': 'Dishwasher Effective voltage',
|
||||
'state_class': <SensorStateClass.MEASUREMENT: 'measurement'>,
|
||||
'unit_of_measurement': <UnitOfElectricPotential.VOLT: 'V'>,
|
||||
}),
|
||||
'context': <ANY>,
|
||||
'entity_id': 'sensor.dishwasher_effective_voltage',
|
||||
'last_changed': <ANY>,
|
||||
'last_reported': <ANY>,
|
||||
'last_updated': <ANY>,
|
||||
'state': '120.0',
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[silabs_dishwasher][sensor.dishwasher_energy-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
@@ -4574,65 +4633,6 @@
|
||||
'state': '0.0',
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[silabs_dishwasher][sensor.dishwasher_voltage-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
}),
|
||||
'area_id': None,
|
||||
'capabilities': dict({
|
||||
'state_class': <SensorStateClass.MEASUREMENT: 'measurement'>,
|
||||
}),
|
||||
'config_entry_id': <ANY>,
|
||||
'config_subentry_id': <ANY>,
|
||||
'device_class': None,
|
||||
'device_id': <ANY>,
|
||||
'disabled_by': None,
|
||||
'domain': 'sensor',
|
||||
'entity_category': <EntityCategory.DIAGNOSTIC: 'diagnostic'>,
|
||||
'entity_id': 'sensor.dishwasher_voltage',
|
||||
'has_entity_name': True,
|
||||
'hidden_by': None,
|
||||
'icon': None,
|
||||
'id': <ANY>,
|
||||
'labels': set({
|
||||
}),
|
||||
'name': None,
|
||||
'options': dict({
|
||||
'sensor': dict({
|
||||
'suggested_display_precision': 0,
|
||||
}),
|
||||
'sensor.private': dict({
|
||||
'suggested_unit_of_measurement': <UnitOfElectricPotential.VOLT: 'V'>,
|
||||
}),
|
||||
}),
|
||||
'original_device_class': <SensorDeviceClass.VOLTAGE: 'voltage'>,
|
||||
'original_icon': None,
|
||||
'original_name': 'Voltage',
|
||||
'platform': 'matter',
|
||||
'previous_unique_id': None,
|
||||
'suggested_object_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': None,
|
||||
'unique_id': '00000000000004D2-0000000000000036-MatterNodeDevice-2-ElectricalPowerMeasurementVoltage-144-4',
|
||||
'unit_of_measurement': <UnitOfElectricPotential.VOLT: 'V'>,
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[silabs_dishwasher][sensor.dishwasher_voltage-state]
|
||||
StateSnapshot({
|
||||
'attributes': ReadOnlyDict({
|
||||
'device_class': 'voltage',
|
||||
'friendly_name': 'Dishwasher Voltage',
|
||||
'state_class': <SensorStateClass.MEASUREMENT: 'measurement'>,
|
||||
'unit_of_measurement': <UnitOfElectricPotential.VOLT: 'V'>,
|
||||
}),
|
||||
'context': <ANY>,
|
||||
'entity_id': 'sensor.dishwasher_voltage',
|
||||
'last_changed': <ANY>,
|
||||
'last_reported': <ANY>,
|
||||
'last_updated': <ANY>,
|
||||
'state': '120.0',
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[silabs_evse_charging][sensor.evse_appliance_energy_state-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
@@ -5134,65 +5134,6 @@
|
||||
'state': '32.0',
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[silabs_laundrywasher][sensor.laundrywasher_current-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
}),
|
||||
'area_id': None,
|
||||
'capabilities': dict({
|
||||
'state_class': <SensorStateClass.MEASUREMENT: 'measurement'>,
|
||||
}),
|
||||
'config_entry_id': <ANY>,
|
||||
'config_subentry_id': <ANY>,
|
||||
'device_class': None,
|
||||
'device_id': <ANY>,
|
||||
'disabled_by': None,
|
||||
'domain': 'sensor',
|
||||
'entity_category': <EntityCategory.DIAGNOSTIC: 'diagnostic'>,
|
||||
'entity_id': 'sensor.laundrywasher_current',
|
||||
'has_entity_name': True,
|
||||
'hidden_by': None,
|
||||
'icon': None,
|
||||
'id': <ANY>,
|
||||
'labels': set({
|
||||
}),
|
||||
'name': None,
|
||||
'options': dict({
|
||||
'sensor': dict({
|
||||
'suggested_display_precision': 2,
|
||||
}),
|
||||
'sensor.private': dict({
|
||||
'suggested_unit_of_measurement': <UnitOfElectricCurrent.AMPERE: 'A'>,
|
||||
}),
|
||||
}),
|
||||
'original_device_class': <SensorDeviceClass.CURRENT: 'current'>,
|
||||
'original_icon': None,
|
||||
'original_name': 'Current',
|
||||
'platform': 'matter',
|
||||
'previous_unique_id': None,
|
||||
'suggested_object_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': None,
|
||||
'unique_id': '00000000000004D2-000000000000001D-MatterNodeDevice-2-ElectricalPowerMeasurementActiveCurrent-144-5',
|
||||
'unit_of_measurement': <UnitOfElectricCurrent.AMPERE: 'A'>,
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[silabs_laundrywasher][sensor.laundrywasher_current-state]
|
||||
StateSnapshot({
|
||||
'attributes': ReadOnlyDict({
|
||||
'device_class': 'current',
|
||||
'friendly_name': 'LaundryWasher Current',
|
||||
'state_class': <SensorStateClass.MEASUREMENT: 'measurement'>,
|
||||
'unit_of_measurement': <UnitOfElectricCurrent.AMPERE: 'A'>,
|
||||
}),
|
||||
'context': <ANY>,
|
||||
'entity_id': 'sensor.laundrywasher_current',
|
||||
'last_changed': <ANY>,
|
||||
'last_reported': <ANY>,
|
||||
'last_updated': <ANY>,
|
||||
'state': '0.0',
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[silabs_laundrywasher][sensor.laundrywasher_current_phase-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
@@ -5253,6 +5194,124 @@
|
||||
'state': 'pre-soak',
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[silabs_laundrywasher][sensor.laundrywasher_effective_current-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
}),
|
||||
'area_id': None,
|
||||
'capabilities': dict({
|
||||
'state_class': <SensorStateClass.MEASUREMENT: 'measurement'>,
|
||||
}),
|
||||
'config_entry_id': <ANY>,
|
||||
'config_subentry_id': <ANY>,
|
||||
'device_class': None,
|
||||
'device_id': <ANY>,
|
||||
'disabled_by': None,
|
||||
'domain': 'sensor',
|
||||
'entity_category': <EntityCategory.DIAGNOSTIC: 'diagnostic'>,
|
||||
'entity_id': 'sensor.laundrywasher_effective_current',
|
||||
'has_entity_name': True,
|
||||
'hidden_by': None,
|
||||
'icon': None,
|
||||
'id': <ANY>,
|
||||
'labels': set({
|
||||
}),
|
||||
'name': None,
|
||||
'options': dict({
|
||||
'sensor': dict({
|
||||
'suggested_display_precision': 2,
|
||||
}),
|
||||
'sensor.private': dict({
|
||||
'suggested_unit_of_measurement': <UnitOfElectricCurrent.AMPERE: 'A'>,
|
||||
}),
|
||||
}),
|
||||
'original_device_class': <SensorDeviceClass.CURRENT: 'current'>,
|
||||
'original_icon': None,
|
||||
'original_name': 'Effective current',
|
||||
'platform': 'matter',
|
||||
'previous_unique_id': None,
|
||||
'suggested_object_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': 'rms_current',
|
||||
'unique_id': '00000000000004D2-000000000000001D-MatterNodeDevice-2-ElectricalPowerMeasurementRMSCurrent-144-12',
|
||||
'unit_of_measurement': <UnitOfElectricCurrent.AMPERE: 'A'>,
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[silabs_laundrywasher][sensor.laundrywasher_effective_current-state]
|
||||
StateSnapshot({
|
||||
'attributes': ReadOnlyDict({
|
||||
'device_class': 'current',
|
||||
'friendly_name': 'LaundryWasher Effective current',
|
||||
'state_class': <SensorStateClass.MEASUREMENT: 'measurement'>,
|
||||
'unit_of_measurement': <UnitOfElectricCurrent.AMPERE: 'A'>,
|
||||
}),
|
||||
'context': <ANY>,
|
||||
'entity_id': 'sensor.laundrywasher_effective_current',
|
||||
'last_changed': <ANY>,
|
||||
'last_reported': <ANY>,
|
||||
'last_updated': <ANY>,
|
||||
'state': '0.0',
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[silabs_laundrywasher][sensor.laundrywasher_effective_voltage-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
}),
|
||||
'area_id': None,
|
||||
'capabilities': dict({
|
||||
'state_class': <SensorStateClass.MEASUREMENT: 'measurement'>,
|
||||
}),
|
||||
'config_entry_id': <ANY>,
|
||||
'config_subentry_id': <ANY>,
|
||||
'device_class': None,
|
||||
'device_id': <ANY>,
|
||||
'disabled_by': None,
|
||||
'domain': 'sensor',
|
||||
'entity_category': <EntityCategory.DIAGNOSTIC: 'diagnostic'>,
|
||||
'entity_id': 'sensor.laundrywasher_effective_voltage',
|
||||
'has_entity_name': True,
|
||||
'hidden_by': None,
|
||||
'icon': None,
|
||||
'id': <ANY>,
|
||||
'labels': set({
|
||||
}),
|
||||
'name': None,
|
||||
'options': dict({
|
||||
'sensor': dict({
|
||||
'suggested_display_precision': 0,
|
||||
}),
|
||||
'sensor.private': dict({
|
||||
'suggested_unit_of_measurement': <UnitOfElectricPotential.VOLT: 'V'>,
|
||||
}),
|
||||
}),
|
||||
'original_device_class': <SensorDeviceClass.VOLTAGE: 'voltage'>,
|
||||
'original_icon': None,
|
||||
'original_name': 'Effective voltage',
|
||||
'platform': 'matter',
|
||||
'previous_unique_id': None,
|
||||
'suggested_object_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': 'rms_voltage',
|
||||
'unique_id': '00000000000004D2-000000000000001D-MatterNodeDevice-2-ElectricalPowerMeasurementRMSVoltage-144-11',
|
||||
'unit_of_measurement': <UnitOfElectricPotential.VOLT: 'V'>,
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[silabs_laundrywasher][sensor.laundrywasher_effective_voltage-state]
|
||||
StateSnapshot({
|
||||
'attributes': ReadOnlyDict({
|
||||
'device_class': 'voltage',
|
||||
'friendly_name': 'LaundryWasher Effective voltage',
|
||||
'state_class': <SensorStateClass.MEASUREMENT: 'measurement'>,
|
||||
'unit_of_measurement': <UnitOfElectricPotential.VOLT: 'V'>,
|
||||
}),
|
||||
'context': <ANY>,
|
||||
'entity_id': 'sensor.laundrywasher_effective_voltage',
|
||||
'last_changed': <ANY>,
|
||||
'last_reported': <ANY>,
|
||||
'last_updated': <ANY>,
|
||||
'state': '120.0',
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[silabs_laundrywasher][sensor.laundrywasher_energy-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
@@ -5433,7 +5492,7 @@
|
||||
'state': '0.0',
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[silabs_laundrywasher][sensor.laundrywasher_voltage-entry]
|
||||
# name: test_sensors[silabs_water_heater][sensor.water_heater_active_current-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
}),
|
||||
@@ -5448,7 +5507,7 @@
|
||||
'disabled_by': None,
|
||||
'domain': 'sensor',
|
||||
'entity_category': <EntityCategory.DIAGNOSTIC: 'diagnostic'>,
|
||||
'entity_id': 'sensor.laundrywasher_voltage',
|
||||
'entity_id': 'sensor.water_heater_active_current',
|
||||
'has_entity_name': True,
|
||||
'hidden_by': None,
|
||||
'icon': None,
|
||||
@@ -5458,38 +5517,38 @@
|
||||
'name': None,
|
||||
'options': dict({
|
||||
'sensor': dict({
|
||||
'suggested_display_precision': 0,
|
||||
'suggested_display_precision': 2,
|
||||
}),
|
||||
'sensor.private': dict({
|
||||
'suggested_unit_of_measurement': <UnitOfElectricPotential.VOLT: 'V'>,
|
||||
'suggested_unit_of_measurement': <UnitOfElectricCurrent.AMPERE: 'A'>,
|
||||
}),
|
||||
}),
|
||||
'original_device_class': <SensorDeviceClass.VOLTAGE: 'voltage'>,
|
||||
'original_device_class': <SensorDeviceClass.CURRENT: 'current'>,
|
||||
'original_icon': None,
|
||||
'original_name': 'Voltage',
|
||||
'original_name': 'Active current',
|
||||
'platform': 'matter',
|
||||
'previous_unique_id': None,
|
||||
'suggested_object_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': None,
|
||||
'unique_id': '00000000000004D2-000000000000001D-MatterNodeDevice-2-ElectricalPowerMeasurementVoltage-144-4',
|
||||
'unit_of_measurement': <UnitOfElectricPotential.VOLT: 'V'>,
|
||||
'translation_key': 'active_current',
|
||||
'unique_id': '00000000000004D2-0000000000000019-MatterNodeDevice-2-ElectricalPowerMeasurementActiveCurrent-144-5',
|
||||
'unit_of_measurement': <UnitOfElectricCurrent.AMPERE: 'A'>,
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[silabs_laundrywasher][sensor.laundrywasher_voltage-state]
|
||||
# name: test_sensors[silabs_water_heater][sensor.water_heater_active_current-state]
|
||||
StateSnapshot({
|
||||
'attributes': ReadOnlyDict({
|
||||
'device_class': 'voltage',
|
||||
'friendly_name': 'LaundryWasher Voltage',
|
||||
'device_class': 'current',
|
||||
'friendly_name': 'Water Heater Active current',
|
||||
'state_class': <SensorStateClass.MEASUREMENT: 'measurement'>,
|
||||
'unit_of_measurement': <UnitOfElectricPotential.VOLT: 'V'>,
|
||||
'unit_of_measurement': <UnitOfElectricCurrent.AMPERE: 'A'>,
|
||||
}),
|
||||
'context': <ANY>,
|
||||
'entity_id': 'sensor.laundrywasher_voltage',
|
||||
'entity_id': 'sensor.water_heater_active_current',
|
||||
'last_changed': <ANY>,
|
||||
'last_reported': <ANY>,
|
||||
'last_updated': <ANY>,
|
||||
'state': '120.0',
|
||||
'state': '0.1',
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[silabs_water_heater][sensor.water_heater_appliance_energy_state-entry]
|
||||
@@ -5556,65 +5615,6 @@
|
||||
'state': 'online',
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[silabs_water_heater][sensor.water_heater_current-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
}),
|
||||
'area_id': None,
|
||||
'capabilities': dict({
|
||||
'state_class': <SensorStateClass.MEASUREMENT: 'measurement'>,
|
||||
}),
|
||||
'config_entry_id': <ANY>,
|
||||
'config_subentry_id': <ANY>,
|
||||
'device_class': None,
|
||||
'device_id': <ANY>,
|
||||
'disabled_by': None,
|
||||
'domain': 'sensor',
|
||||
'entity_category': <EntityCategory.DIAGNOSTIC: 'diagnostic'>,
|
||||
'entity_id': 'sensor.water_heater_current',
|
||||
'has_entity_name': True,
|
||||
'hidden_by': None,
|
||||
'icon': None,
|
||||
'id': <ANY>,
|
||||
'labels': set({
|
||||
}),
|
||||
'name': None,
|
||||
'options': dict({
|
||||
'sensor': dict({
|
||||
'suggested_display_precision': 2,
|
||||
}),
|
||||
'sensor.private': dict({
|
||||
'suggested_unit_of_measurement': <UnitOfElectricCurrent.AMPERE: 'A'>,
|
||||
}),
|
||||
}),
|
||||
'original_device_class': <SensorDeviceClass.CURRENT: 'current'>,
|
||||
'original_icon': None,
|
||||
'original_name': 'Current',
|
||||
'platform': 'matter',
|
||||
'previous_unique_id': None,
|
||||
'suggested_object_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': None,
|
||||
'unique_id': '00000000000004D2-0000000000000019-MatterNodeDevice-2-ElectricalPowerMeasurementActiveCurrent-144-5',
|
||||
'unit_of_measurement': <UnitOfElectricCurrent.AMPERE: 'A'>,
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[silabs_water_heater][sensor.water_heater_current-state]
|
||||
StateSnapshot({
|
||||
'attributes': ReadOnlyDict({
|
||||
'device_class': 'current',
|
||||
'friendly_name': 'Water Heater Current',
|
||||
'state_class': <SensorStateClass.MEASUREMENT: 'measurement'>,
|
||||
'unit_of_measurement': <UnitOfElectricCurrent.AMPERE: 'A'>,
|
||||
}),
|
||||
'context': <ANY>,
|
||||
'entity_id': 'sensor.water_heater_current',
|
||||
'last_changed': <ANY>,
|
||||
'last_reported': <ANY>,
|
||||
'last_updated': <ANY>,
|
||||
'state': '0.1',
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[silabs_water_heater][sensor.water_heater_energy_optimization_opt_out-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
@@ -5941,7 +5941,7 @@
|
||||
'previous_unique_id': None,
|
||||
'suggested_object_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': None,
|
||||
'translation_key': 'voltage',
|
||||
'unique_id': '00000000000004D2-0000000000000019-MatterNodeDevice-2-ElectricalPowerMeasurementVoltage-144-4',
|
||||
'unit_of_measurement': <UnitOfElectricPotential.VOLT: 'V'>,
|
||||
})
|
||||
@@ -6122,7 +6122,7 @@
|
||||
'state': '0.0',
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[solar_power][sensor.solarpower_current-entry]
|
||||
# name: test_sensors[solar_power][sensor.solarpower_active_current-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
}),
|
||||
@@ -6137,7 +6137,7 @@
|
||||
'disabled_by': None,
|
||||
'domain': 'sensor',
|
||||
'entity_category': <EntityCategory.DIAGNOSTIC: 'diagnostic'>,
|
||||
'entity_id': 'sensor.solarpower_current',
|
||||
'entity_id': 'sensor.solarpower_active_current',
|
||||
'has_entity_name': True,
|
||||
'hidden_by': None,
|
||||
'icon': None,
|
||||
@@ -6155,26 +6155,26 @@
|
||||
}),
|
||||
'original_device_class': <SensorDeviceClass.CURRENT: 'current'>,
|
||||
'original_icon': None,
|
||||
'original_name': 'Current',
|
||||
'original_name': 'Active current',
|
||||
'platform': 'matter',
|
||||
'previous_unique_id': None,
|
||||
'suggested_object_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': None,
|
||||
'translation_key': 'active_current',
|
||||
'unique_id': '00000000000004D2-0000000000000001-MatterNodeDevice-1-ElectricalPowerMeasurementActiveCurrent-144-5',
|
||||
'unit_of_measurement': <UnitOfElectricCurrent.AMPERE: 'A'>,
|
||||
})
|
||||
# ---
|
||||
# name: test_sensors[solar_power][sensor.solarpower_current-state]
|
||||
# name: test_sensors[solar_power][sensor.solarpower_active_current-state]
|
||||
StateSnapshot({
|
||||
'attributes': ReadOnlyDict({
|
||||
'device_class': 'current',
|
||||
'friendly_name': 'SolarPower Current',
|
||||
'friendly_name': 'SolarPower Active current',
|
||||
'state_class': <SensorStateClass.MEASUREMENT: 'measurement'>,
|
||||
'unit_of_measurement': <UnitOfElectricCurrent.AMPERE: 'A'>,
|
||||
}),
|
||||
'context': <ANY>,
|
||||
'entity_id': 'sensor.solarpower_current',
|
||||
'entity_id': 'sensor.solarpower_active_current',
|
||||
'last_changed': <ANY>,
|
||||
'last_reported': <ANY>,
|
||||
'last_updated': <ANY>,
|
||||
@@ -6337,7 +6337,7 @@
|
||||
'previous_unique_id': None,
|
||||
'suggested_object_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': None,
|
||||
'translation_key': 'voltage',
|
||||
'unique_id': '00000000000004D2-0000000000000001-MatterNodeDevice-1-ElectricalPowerMeasurementVoltage-144-4',
|
||||
'unit_of_measurement': <UnitOfElectricPotential.VOLT: 'V'>,
|
||||
})
|
||||
|
||||
Reference in New Issue