Fix KNX sensor default attributes for energy and volume DPTs (#164838)

Co-authored-by: Copilot <175728472+Copilot@users.noreply.github.com>
This commit is contained in:
Matthias Alphart
2026-03-05 16:48:47 +01:00
committed by Franck Nijhof
parent 6b30969f60
commit 98ac6dd2c1
2 changed files with 56 additions and 11 deletions

View File

@@ -8,6 +8,7 @@ from xknx.dpt import DPTBase, DPTComplex, DPTEnum, DPTNumeric
from xknx.dpt.dpt_16 import DPTString
from homeassistant.components.sensor import SensorDeviceClass, SensorStateClass
from homeassistant.const import UnitOfReactiveEnergy
HaDptClass = Literal["numeric", "enum", "complex", "string"]
@@ -36,7 +37,7 @@ def get_supported_dpts() -> Mapping[str, DPTInfo]:
main=dpt_class.dpt_main_number, # type: ignore[typeddict-item] # checked in xknx unit tests
sub=dpt_class.dpt_sub_number,
name=dpt_class.value_type,
unit=dpt_class.unit,
unit=_sensor_unit_overrides.get(dpt_number_str, dpt_class.unit),
sensor_device_class=_sensor_device_classes.get(dpt_number_str),
sensor_state_class=_get_sensor_state_class(ha_dpt_class, dpt_number_str),
)
@@ -77,13 +78,13 @@ _sensor_device_classes: Mapping[str, SensorDeviceClass] = {
"12.1200": SensorDeviceClass.VOLUME,
"12.1201": SensorDeviceClass.VOLUME,
"13.002": SensorDeviceClass.VOLUME_FLOW_RATE,
"13.010": SensorDeviceClass.ENERGY,
"13.012": SensorDeviceClass.REACTIVE_ENERGY,
"13.013": SensorDeviceClass.ENERGY,
"13.015": SensorDeviceClass.REACTIVE_ENERGY,
"13.016": SensorDeviceClass.ENERGY,
"13.1200": SensorDeviceClass.VOLUME,
"13.1201": SensorDeviceClass.VOLUME,
"13.010": SensorDeviceClass.ENERGY, # DPTActiveEnergy
"13.012": SensorDeviceClass.REACTIVE_ENERGY, # DPTReactiveEnergy
"13.013": SensorDeviceClass.ENERGY, # DPTActiveEnergykWh
"13.015": SensorDeviceClass.REACTIVE_ENERGY, # DPTReactiveEnergykVARh
"13.016": SensorDeviceClass.ENERGY, # DPTActiveEnergyMWh
"13.1200": SensorDeviceClass.VOLUME, # DPTDeltaVolumeLiquidLitre
"13.1201": SensorDeviceClass.VOLUME, # DPTDeltaVolumeM3
"14.010": SensorDeviceClass.AREA,
"14.019": SensorDeviceClass.CURRENT,
"14.027": SensorDeviceClass.VOLTAGE,
@@ -91,7 +92,7 @@ _sensor_device_classes: Mapping[str, SensorDeviceClass] = {
"14.030": SensorDeviceClass.VOLTAGE,
"14.031": SensorDeviceClass.ENERGY,
"14.033": SensorDeviceClass.FREQUENCY,
"14.037": SensorDeviceClass.ENERGY_STORAGE,
"14.037": SensorDeviceClass.ENERGY_STORAGE, # DPTHeatQuantity
"14.039": SensorDeviceClass.DISTANCE,
"14.051": SensorDeviceClass.WEIGHT,
"14.056": SensorDeviceClass.POWER,
@@ -101,7 +102,7 @@ _sensor_device_classes: Mapping[str, SensorDeviceClass] = {
"14.068": SensorDeviceClass.TEMPERATURE,
"14.069": SensorDeviceClass.TEMPERATURE,
"14.070": SensorDeviceClass.TEMPERATURE_DELTA,
"14.076": SensorDeviceClass.VOLUME,
"14.076": SensorDeviceClass.VOLUME, # DPTVolume
"14.077": SensorDeviceClass.VOLUME_FLOW_RATE,
"14.080": SensorDeviceClass.APPARENT_POWER,
"14.1200": SensorDeviceClass.VOLUME_FLOW_RATE,
@@ -121,17 +122,28 @@ _sensor_state_class_overrides: Mapping[str, SensorStateClass | None] = {
"13.010": SensorStateClass.TOTAL, # DPTActiveEnergy
"13.011": SensorStateClass.TOTAL, # DPTApparantEnergy
"13.012": SensorStateClass.TOTAL, # DPTReactiveEnergy
"13.013": SensorStateClass.TOTAL, # DPTActiveEnergykWh
"13.015": SensorStateClass.TOTAL, # DPTReactiveEnergykVARh
"13.016": SensorStateClass.TOTAL, # DPTActiveEnergyMWh
"13.1200": SensorStateClass.TOTAL, # DPTDeltaVolumeLiquidLitre
"13.1201": SensorStateClass.TOTAL, # DPTDeltaVolumeM3
"14.007": SensorStateClass.MEASUREMENT_ANGLE, # DPTAngleDeg
"14.037": SensorStateClass.TOTAL, # DPTHeatQuantity
"14.051": SensorStateClass.TOTAL, # DPTMass
"14.055": SensorStateClass.MEASUREMENT_ANGLE, # DPTPhaseAngleDeg
"14.031": SensorStateClass.TOTAL_INCREASING, # DPTEnergy
"14.076": SensorStateClass.TOTAL, # DPTVolume
"17.001": None, # DPTSceneNumber
"29.010": SensorStateClass.TOTAL, # DPTActiveEnergy8Byte
"29.011": SensorStateClass.TOTAL, # DPTApparantEnergy8Byte
"29.012": SensorStateClass.TOTAL, # DPTReactiveEnergy8Byte
}
_sensor_unit_overrides: Mapping[str, str] = {
"13.012": UnitOfReactiveEnergy.VOLT_AMPERE_REACTIVE_HOUR, # DPTReactiveEnergy (VARh in KNX)
"13.015": UnitOfReactiveEnergy.KILO_VOLT_AMPERE_REACTIVE_HOUR, # DPTReactiveEnergykVARh (kVARh in KNX)
"29.012": UnitOfReactiveEnergy.VOLT_AMPERE_REACTIVE_HOUR, # DPTReactiveEnergy8Byte (VARh in KNX)
}
def _get_sensor_state_class(
ha_dpt_class: HaDptClass, dpt_number_str: str

View File

@@ -0,0 +1,33 @@
"""Test KNX DPT default attributes."""
import pytest
from homeassistant.components.knx.dpt import (
_sensor_device_classes,
_sensor_state_class_overrides,
_sensor_unit_overrides,
)
from homeassistant.components.knx.schema import _sensor_attribute_sub_validator
@pytest.mark.parametrize(
"dpt",
sorted(
{
*_sensor_device_classes,
*_sensor_state_class_overrides,
*_sensor_unit_overrides,
# add generic numeric DPTs without specific device and state class
"7",
"2byte_float",
}
),
)
def test_dpt_default_device_classes(dpt: str) -> None:
"""Test DPT default device and state classes and unit are valid."""
assert _sensor_attribute_sub_validator(
# YAML sensor config - only set type for this validation
# other keys are not required for this test
# UI validation works the same way, but uses different schema for config
{"type": dpt}
)