Initialize quality scale in hvv_departures (#172867)
This commit is contained in:
@@ -0,0 +1,171 @@
|
||||
rules:
|
||||
# Bronze
|
||||
action-setup:
|
||||
status: exempt
|
||||
comment: The integration does not register any custom actions or services.
|
||||
appropriate-polling: done
|
||||
brands: done
|
||||
common-modules:
|
||||
status: todo
|
||||
comment: >-
|
||||
The DataUpdateCoordinator is defined inline inside async_setup_entry in
|
||||
binary_sensor.py rather than in a dedicated coordinator.py.
|
||||
The sensor.py should also use the dedicated coordinator.
|
||||
|
||||
Nice to have: a shared base entity in entity.py.
|
||||
config-flow-test-coverage:
|
||||
status: todo
|
||||
comment: >-
|
||||
A test verifying that the config flow prevents duplicate entries is
|
||||
missing. This is related to the missing unique-config-entry
|
||||
implementation.
|
||||
All tests should end in CREATE_ENTRY or ABORT to test that the flow is
|
||||
able to recover.
|
||||
config-flow:
|
||||
status: todo
|
||||
comment: >-
|
||||
The config flow is functional but does not use data_description in
|
||||
strings.json to give users context for the input fields (host,
|
||||
username, password).
|
||||
|
||||
Todos that are not blocking `done`:
|
||||
- Move to a sub entry flow for adding stations (single config flow
|
||||
for auth, sub entry for every station)
|
||||
- Remove `host` as there is no expected use case for
|
||||
other-than-default hosts
|
||||
dependency-transparency: done
|
||||
docs-actions:
|
||||
status: exempt
|
||||
comment: The integration does not provide any custom actions.
|
||||
docs-high-level-description: done
|
||||
docs-installation-instructions: done
|
||||
docs-removal-instructions:
|
||||
status: todo
|
||||
comment: The integration documentation does not include a removal instructions section.
|
||||
entity-event-setup:
|
||||
status: exempt
|
||||
comment: The integration entities do not subscribe to any events.
|
||||
entity-unique-id: done
|
||||
has-entity-name: done
|
||||
runtime-data: done
|
||||
test-before-configure: done
|
||||
test-before-setup:
|
||||
status: todo
|
||||
comment: >-
|
||||
async_setup_entry in __init__.py forwards to platforms without verifying
|
||||
connectivity first. No ConfigEntryNotReady or ConfigEntryAuthFailed is
|
||||
raised on connection failure.
|
||||
unique-config-entry:
|
||||
status: todo
|
||||
comment: >-
|
||||
The config flow does not call async_set_unique_id() or
|
||||
_abort_if_unique_id_configured(). The "already_configured" abort string
|
||||
exists in strings.json but is never triggered.
|
||||
|
||||
# Silver
|
||||
action-exceptions:
|
||||
status: exempt
|
||||
comment: The integration does not provide any custom actions.
|
||||
config-entry-unloading: done
|
||||
docs-configuration-parameters: done
|
||||
docs-installation-parameters: done
|
||||
entity-unavailable: done
|
||||
integration-owner: done
|
||||
log-when-unavailable: done
|
||||
parallel-updates:
|
||||
status: todo
|
||||
comment: >-
|
||||
sensor.py defines PARALLEL_UPDATES = 0, but binary_sensor.py is missing
|
||||
the PARALLEL_UPDATES constant entirely.
|
||||
reauthentication-flow:
|
||||
status: todo
|
||||
comment: >-
|
||||
The integration requires username and password credentials but does not
|
||||
implement async_step_reauth.
|
||||
test-coverage:
|
||||
status: todo
|
||||
comment: >-
|
||||
Only the config flow is tested (test_config_flow.py). There are no tests
|
||||
for sensor.py or binary_sensor.py, so coverage is well below 95%.
|
||||
|
||||
# Gold
|
||||
devices: done
|
||||
diagnostics:
|
||||
status: todo
|
||||
comment: No diagnostics.py module exists.
|
||||
discovery-update-info:
|
||||
status: exempt
|
||||
comment: >-
|
||||
The integration connects to a cloud API (HVV GTI) that has no network
|
||||
discovery mechanism.
|
||||
discovery:
|
||||
status: exempt
|
||||
comment: >-
|
||||
The HVV GTI API requires user-supplied credentials and cannot be
|
||||
auto-discovered.
|
||||
docs-data-update:
|
||||
status: todo
|
||||
comment: >-
|
||||
The documentation does not describe polling intervals (1 minute for
|
||||
departures, 1 hour for elevator status).
|
||||
docs-examples:
|
||||
status: todo
|
||||
comment: The documentation does not include blueprints or usage examples.
|
||||
docs-known-limitations:
|
||||
status: todo
|
||||
comment: The documentation does not include a Known Limitations section.
|
||||
docs-supported-devices:
|
||||
status: exempt
|
||||
comment: >-
|
||||
The integration connects to a cloud transit data service and does not
|
||||
integrate physical devices.
|
||||
docs-supported-functions: done
|
||||
docs-troubleshooting:
|
||||
status: todo
|
||||
comment: The documentation does not include a troubleshooting section.
|
||||
docs-use-cases:
|
||||
status: todo
|
||||
comment: The documentation does not include use-case examples.
|
||||
dynamic-devices:
|
||||
status: todo
|
||||
comment: >-
|
||||
binary_sensor.py only adds elevator entities at initial setup. There is
|
||||
no coordinator listener to dynamically add entities for elevators that
|
||||
appear in subsequent coordinator refreshes.
|
||||
entity-category: done
|
||||
entity-device-class: done
|
||||
entity-disabled-by-default: done
|
||||
entity-translations:
|
||||
status: todo
|
||||
comment: >-
|
||||
binary_sensor.py sets _attr_name to a hardcoded English string
|
||||
("Elevator {label}", "Unknown elevator") constructed in
|
||||
get_elevator_entities_from_station_information, rather than using a
|
||||
translation key. The sensor entity correctly uses _attr_translation_key.
|
||||
exception-translations:
|
||||
status: todo
|
||||
comment: >-
|
||||
No exceptions use translation_domain or translation_key. There is no
|
||||
"exceptions" section in strings.json.
|
||||
icon-translations: done
|
||||
reconfiguration-flow:
|
||||
status: todo
|
||||
comment: No async_step_reconfigure is implemented in config_flow.py.
|
||||
repair-issues:
|
||||
status: todo
|
||||
comment: >-
|
||||
If a configured station no longer exists in the GTI API, or if the
|
||||
saved line filters reference lines that have been removed, the
|
||||
integration should surface a repair issue to guide the user to
|
||||
reconfigure.
|
||||
stale-devices:
|
||||
status: todo
|
||||
comment: >-
|
||||
There is no async_remove_config_entry_device implementation. Elevator
|
||||
entities persist in the registry even if the station's elevator
|
||||
configuration changes.
|
||||
|
||||
# Platinum
|
||||
async-dependency: done
|
||||
inject-websession: done
|
||||
strict-typing: done
|
||||
@@ -445,7 +445,6 @@ INTEGRATIONS_WITHOUT_QUALITY_SCALE_FILE = [
|
||||
"huisbaasje",
|
||||
"hunterdouglas_powerview",
|
||||
"husqvarna_automower_ble",
|
||||
"hvv_departures",
|
||||
"hydrawise",
|
||||
"hyperion",
|
||||
"ialarm",
|
||||
|
||||